PRODUCTS
Brief introduction:Qd-8d has four independent channel outputs. It is suitable for single-phase, two-phase and four phase piezoelectric transducers, such as various piezoelectric transducers such as ultrasonic motor, vibration cutting, ultrasonic cleaning and ultrasonic welding. It has large output power, wide parameter adjustment range and various parameters can be set independently to meet the experimental and test requirements of various piezoelectric transducers.
Characteristic:
Super versatility, without impedance matching, can be directly used in all kinds of piezoelectric oscillators
Intuitive and convenient operation, multi parameter digital display and setting, which can expand computer communication
Stable and reliable operation, stable waveform, multiple protection logic, long-term practical test
Application:
Single phase, two-phase, three-phase and four phase ultrasonic transducers, such as ultrasonic mold, ultrasonic motor, etc.
The four channels have the same frequency and different phases, which can excite multiple modes.
Specifications:
output power
Overall dimension | About 320mm long × 300mm wide × 130mm high |
weight | About 12kg |
display | Dual SMS code breaking display + 12864 LCD |
Power Supply | AV220V/50Hz |
Each phase can output 200W independently, but the total power does not exceed 400W |
output:
name | meaning | Adjustment range | Stepping |
frequency(Freq) | output frequency | 100Hz~200 kHz | F2/60000000 Hz Minimum 10Hz |
A. Phase B voltage (Vo1) | Peak to peak of output voltage | 10~500 V | Continuous regulation |
C. Phase D voltage (VO2) | Peak to peak of output voltage | 10~500 V | Continuous regulation |
Phase (P) | A. B phase difference of two phases | 0~360° | 0.1° |
A. C phase difference between two phases | 0~360° | 0.1° | |
B. D phase difference between two phases | 180° | Non adjustable | |
Mode | Carrier speed regulation mode | No carrier/ Pulse cluster | —— |
Top